Trade Price
POA
Per
1
Unit
Pack Quantity
This passive filter is an option for variable speed drives of Altivar range. Its rated current is equal to 75A. It is used as an input filter in order to obtain total harmonic distortion of less than 10% or 5%. Its protection index is IP20. It weighs 98kg and its dimensions are, 378mm wide, 623.6mm high, 333mm deep. It is designed to be used for drives in the first environment (restricted distribution, domestic applications).
Product or component type
Passive filter
Product specific application
Reduction of current harmonics
Range compatibility
Altivar 71 Altivar 61 Altivar Process ATV600 Altivar Process ATV900
[Us] rated supply voltage
400 V +/- 10 %
power supply frequency
50 Hz +/- 2 %
Quantity per drive
1 filter per drive for variable speed drive ATV61W motor: 37 kW/50 hp 1 filter per drive for variable speed drive ATV61H motor: 37 kW/50 hp 1 filter per drive for variable speed drive ATV71H motor: 37 kW/50 hp 1 filter per drive for variable speed drive ATV71W motor: 37 kW/50 hp
[In] rated current
72 A for input 75 A for output
Network number of phases
3 phases
THDI
10 % for variable speed drive ATV61H motor: 37 kW/50 hp 10 % for variable speed drive ATV71H motor: 37 kW/50 hp 10 % for variable speed drive ATV71W motor: 37 kW/50 hp 5 % for variable speed drive ATV61W motor: 37 kW/50 hp
Max current
1.5 x nominal current (duration = 60 s)
Efficiency
98 %
Thermal losses
688 W
Cos phi
1 (150 % of line current) 0.85 (75 % of line current) 0.99 (100 % of line current)
Electrical connection
A, B terminal, connection capacity: 2.5 mm² X1-1...X2-3 terminal, connection capacity: 2.5...50 mm²
Electrical insulation class
Class F
Net weight
98 kg
IP degree of protection
IP20 IP55 (enclosure mounting)
Vibration resistance
2 mm peak to peak (f= 5…13.2 Hz) conforming to EN 60068-2-6 0.7 gn (f= 13.2…150 Hz) conforming to EN 60068-2-6
Relative humidity
5…85 % without condensation
Ambient air temperature for operation
45…60 °C (with current derating 3 % per °C) 5…45 °C (without current derating)
Ambient air temperature for storage
-25…55 °C storage in original packaging -25…65 °C during transport
Operating altitude
<= 1000 m without current derating > 1000...4000 m with current derating 5 % per 1000 m
Standards
EN/IEC 61000-2-4 EN/IEC 61000-3-12 G5/4 engineering recommendation EN/IEC 61000-2-2 EN/IEC 61000-3-4 EN/IEC 61000-3-2
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
61.000 cm
Package 1 Width
60.000 cm
Package 1 Length
80.000 cm
Package 1 Weight
110.2 kg
Warranty
18 months
Datasheet